Mode 6 is designed to allow access to the results of onboard diagnostic monitoring tests of specific components/systems that are not continuously monitored. These systems include the catalytic converter, EVAP system, oxygen sensor, oxygen sensor heater, EGR system, secondary AIR system, and sometimes misfire.
Mode 6 data is output from the PCM/ECM in hexadecimal form. The $ sign indicates a hexadecimal number. Depending on the software in the scanner, the output could be displayed in hexadecimal numbers (no conversion), raw data (conversion to decimal numbers), or measurable values (applying conversion factor to raw data).
Before reading mode 6 information, ensure that the monitor for the information you are accessing has run to completion. If the monitor is not complete, the mode 6 data will not be accurate.
Mode $06 Test ID by Model
Monitor
Test ID
Test Limit Type and Comp. ID
TSX
3.5 RL
NSX
RSX
MDX
TL
EGR Flow
$01
$80
X
X
$03
$81
X
X
Catalyst (Bank 1)
$04
$02
X
$05/$06
$81/$81
X
X
$62
$04
X
X
X
Catalyst (Bank 2)
$07/$0A
$81/$81
X
$64
$04
X
X
A/F Sensor Heater (Bank 1)
$70/$71/$72
$80/$00/$00
X
PHO2S Heater (Bank 1)
$10/$11
$85/$05
X
$10/$11
$88/$08
X
SHO2S Heater (Bank 1)
$18/$19
$85/$05
X
$18/$19
$86/$06
X
X
$18/$19
$89/$09
X
X
PHO2S Heater (Bank 2)
$12/$13
$85/$05
X
$12/$13
$88/$08
X
SHO2S Heater (Bank 2)
$1A/$1B
$86/$06
X
$1A/$1B
$89/$09
X
PCV
$48
$00
X
$48
$01
X
X
X
Thermostat
$4D/$4E/$4F/$50
$80/$80/$80/$00
X
X
$4D/$4E/$4F/$50
$81/$81/$81/$01
X
X
$5C/$5D/$5E/$5F
$00/$00/$00/$00
X
Secondary Air System
$58/$59/$5A
$80/$00/$80
X
$5B
$00
X
EVAP System
$21/$26/$27/$38
$83/$83/$83/$03
X
X
X
$29/$2D/2E/$2F
$83/$03/83/$83
X
X
X
$3A/$3B/$3C
$83/$83/$03
X
X
X
$3E
$83
X
X
X
$81
$80
X
X
X
$82/$8F
$80/$80
X
X
X
$83
$00
X
$85
$00
X
$86
$00
X
$87
$00
X
$88
$00
X
X
$8B/$8D
$00/$00
X
X
$90/$91/$92/$93
$00/$80/$80/$00
X
X
$94/$95/$96/$97
$00/$80/$00/$00
X
X
$98
$00
X
DTC P0401: Test ID $01: Component ID $80
Test ID
$01
Test Limit Type and Component ID
$80
DTC
P0401
Test Description
Check EGR flow by monitoring the change in intake manifold pressure between EGR valve open and closed during fuel cut.
Store Timing
Normal judgement/Failure judgement
Conversion to Engineering Units
Measured value: Output value (Decimal) x 1.34 (mmHg)
The lowest limit value: Output value (Decimal) x 1.34 (mmHg)
The highest limit value: Not applicable
DTC P0401: Test ID $03: Component ID $81
Test ID
$03
Test Limit Type and Component ID
$81
DTC
P0401
Test Description
Check EGR flow by monitoring the change in intake manifold pressure between EGR valve open and closed during fuel cut.
Store Timing
Normal judgement/Failure judgement
Conversion to Engineering Units
Measured value: Output value (Decimal) x 0.1 (%)
The lowest limit value: Output value (Decimal) x 0.1 (%)
The highest limit value: Not applicable
DTC P0420: Test ID $04: Component ID $02
Test ID
$04
Test Limit Type and Component ID
$02
DTC
P0420
Test Description
Catalyst capability, monitored by measuring the fluctuation of the secondary oxygen sensor output value.
Store Timing
Normal judgement/Failure judgement
Conversion to Engineering Units
Measured value: No unit
The lowest limit value: Not applicable
The highest limit value: No unit
DTC P0420: Test ID $05: Component ID $81
Test ID
$05
Test Limit Type and Component ID
$81
DTC
P0420
Test Description
Catalyst capability monitored by OSC index. OSC index is calculated from the secondary oxygen sensor signal during the secondary oxygen sensor feedback control.
Store Timing
Normal judgement/Failure judgement
Conversion to Engineering Units
Measured value: No unit
The lowest limit value: No unit
The highest limit value: Not applicable
DTC P0420: Test ID $06: Component ID $81
Test ID
$06
Test Limit Type and Component ID
$81
DTC
P0420
Test Description
Catalyst capability monitored by the secondary oxygen sensor signal during the secondary oxygen sensor feedback control.
Store Timing
Normal judgement
Conversion to Engineering Units
Measured value: Output value x 10 (msec.)
The lowest limit value: Output value x 10 (msec.)
The highest limit value: Not applicable
DTC P0420: Test ID $62: Component ID $04
Test ID
$62
Test Limit Type and Component ID
$04
DTC
P0420
Test Description
Catalyst capability, monitored by measuring the fluctuation of the secondary oxygen sensor.
Store Timing
Normal judgement/Failure judgement
Conversion to Engineering Units
Measured value: No unit
The lowest limit value: Not applicable
The highest limit value: No unit
DTC P0420: Test ID $07: Component ID $81
Test ID
$07
Test Limit Type and Component ID
$81
DTC
P0420
Test Description
Catalyst capability monitored by the secondary oxygen sensor signal during the secondary oxygen sensor feedback control.
Store Timing
Normal judgement
Conversion to Engineering Units
Measured value: Output value x 10 (msec.)
The lowest limit value: Output value x 10 (msec.)
The highest limit value: Not applicable
DTC P0430: Test ID $0A: Component ID $81
Test ID
$0A
Test Limit Type and Component ID
$81
DTC
P0430
Test Description
Catalyst capability monitored by measuring the fluctuation of the secondly oxygen sensor output value.
Store Timing
Normal judgement/Failure judgement
Conversion to Engineering Units
Measured value: No unit
The lowest limit value: No unit
The highest limit value: Not applicable
DTC P0430: Test ID $64: Component ID $04
Test ID
$64
Test Limit Type and Component ID
$04
DTC
P0430
Test Description
Catalyst capability, monitored by measuring the fluctuation of the secondary oxygen sensor.
Store Timing
Normal judgement/Failure judgement
Conversion to Engineering Units
Measured value: No unit
The lowest limit value: Not applicable
The highest limit value: No unit
DTC P0135: Test ID $70: Component ID $80
Test ID
$70
Test Limit Type and Component ID
$80
DTC
P0135
Test Description
Circuit check of A/F sensor heater by monitoring the sensor output current during heater on.
Store Timing
Normal judgement/Failure judgement
Conversion to Engineering Units
Measured value: Output value (Decimal) x 0.01 (A)
The lowest limit value: Output value (Decimal) x 0.01 (A)
The highest limit value: Not applicable
DTC P0135: Test ID $71: Component ID $00
Test ID
$71
Test Limit Type and Component ID
$00
DTC
P0135
Test Description
Circuit check of A/F sensor heater by monitoring the sensor output current during heater on.
Store Timing
Normal judgement/Failure judgement
Conversion to Engineering Units
Measured value: Output value (Decimal) x 0.01 (A)
The lowest limit value: Not applicable
The highest limit value: Output value (Decimal) x 0.01 (A)
DTC P0135: Test ID $72: Component ID $00
Test ID
$72
Test Limit Type and Component ID
$00
DTC
P0135
Test Description
Circuit check of A/F sensor heater by monitoring the sensor output current during heater off.
Store Timing
Normal judgement/Failure judgement
Conversion to Engineering Units
Measured value: Output value (Decimal) x 0.01 (A)
The lowest limit value: Not applicable
The highest limit value: Output value (Decimal) x 0.01 (A)
DTC P0135: Test ID $10: Component ID $85
Test ID
$10
Test Limit Type and Component ID
$85
DTC
P0135
Test Description
Circuit check of A/F sensor heater by monitoring the sensor output current during heater on.
Store Timing
Normal judgement/Failure judgement
Conversion to Engineering Units
Measured value: Output value x 26.7 (mA)
The lowest limit value: Output value x 26.7 (mA)
The highest limit value: Not applicable
DTC P0135: Test ID $11: Component ID $05
Test ID
$11
Test Limit Type and Component ID
$05
DTC
P0135
Test Description
Circuit check of A/F sensor heater by monitoring the sensor output current during heater on.
Store Timing
Normal judgement/Failure judgement
Conversion to Engineering Units
Measured value: Output value x 26.7 (mA)
The lowest limit value: Not applicable
The highest limit value: Output value x 26.7 (mA)
DTC P0135: Test ID $10: Component ID $88
Test ID
$10
Test Limit Type and Component ID
$88
DTC
P0135
Test Description
Circuit check of A/F sensor heater by monitoring the sensor output current during heater on.
Store Timing
Normal judgement/Failure judgement
Conversion to Engineering Units
Measured value: Output value (Decimal) x 9.042 (mA)
The lowest limit value: Output value (Decimal) x 9.042 (mA)
The highest limit value: Not applicable
DTC P0135: Test ID $11: Component ID $08
Test ID
$11
Test Limit Type and Component ID
$08
DTC
P0135
Test Description
Circuit check of A/F sensor heater by monitoring the sensor output current during heater on.
Store Timing
Normal judgement/Failure judgement
Conversion to Engineering Units
Measured value: Output value (Decimal) x 9.042 (mA)
The lowest limit value: Not applicable
The highest limit value: Output value (Decimal) x 9.042 (mA)
DTC P0141: Test ID $18: Component ID $85
Test ID
$18
Test Limit Type and Component ID
$85
DTC
P0141
Test Description
Circuit check of secondary oxygen sensor heater by monitoring the sensor output current during heater on.
Store Timing
Normal judgement/Failure judgement
Conversion to Engineering Units
Measured value: Output value x 26.7 (mA)
The lowest limit value: Output value x 26.7 (mA)
The highest limit value: Not applicable
DTC P0141: Test ID $19: Component ID $05
Test ID
$19
Test Limit Type and Component ID
$05
DTC
P0141
Test Description
Circuit check of secondary oxygen sensor heater by monitoring the sensor output current during heater on.
Store Timing
Normal judgement/Failure judgement
Conversion to Engineering Units
Measured value: Output value x 26.7 (mA)
The lowest limit value: Not applicable
The highest limit value: Output value x 26.7 (mA)
DTC P0141: Test ID $18: Component ID $86
Test ID
$18
Test Limit Type and Component ID
$86
DTC
P0141
Test Description
Circuit check of secondary oxygen sensor heater by monitoring the sensor output current during heater on.
Store Timing
Normal judgement/Failure judgement
Conversion to Engineering Units
Measured value: Output value x 7.23 (mA)
The lowest limit value: Output value x 7.23 (mA)
The highest limit value: Not applicable
DTC P0141: Test ID $19: Component ID $06
Test ID
$19
Test Limit Type and Component ID
$06
DTC
P0141
Test Description
Circuit check of secondary oxygen sensor heater by monitoring the sensor output current during heater on.
Store Timing
Normal judgement/Failure judgement
Conversion to Engineering Units
Measured value: Output value x 7.23 (mA)
The lowest limit value: Not applicable
The highest limit value: Output value x 7.23 (mA)
DTC P0141: Test ID $18: Component ID $89
Test ID
$18
Test Limit Type and Component ID
$89
DTC
P0141
Test Description
Circuit check of secondary oxygen sensor heater by monitoring the sensor output current during heater on.
Store Timing
Normal judgement/Failure judgement
Conversion to Engineering Units
Measured value: Output value (Decimal) x 0.01 (A)
The lowest limit value: Output value (Decimal) x 0.01 (A)
The highest limit value: Not applicable
DTC P0141: Test ID $19: Component ID $09
Test ID
$19
Test Limit Type and Component ID
$09
DTC
P0141
Test Description
Circuit check of secondary oxygen sensor heater by monitoring the sensor output current during heater on.
Store Timing
Normal judgement/Failure judgement
Conversion to Engineering Units
Measured value: Output value (Decimal) x 0.01 (A)
The lowest limit value: Not applicable
The highest limit value: Output value (Decimal) x 0.01 (A)
DTC P0155: Test ID $12: Component ID $85
Test ID
$12
Test Limit Type and Component ID
$85
DTC
P0155
Test Description
Circuit check of A/F sensor heater by monitoring the sensor output current during heater on.
Store Timing
Normal judgement/Failure judgement
Conversion to Engineering Units
Measured value: Output value x 26.7 (mA)
The lowest limit value: Output value x 26.7 (mA)
The highest limit value: Not applicable
DTC P0155: Test ID $13: Component ID $05
Test ID
$13
Test Limit Type and Component ID
$05
DTC
P0155
Test Description
Circuit check of A/F sensor heater by monitoring the sensor output current during heater on.
Store Timing
Normal judgement/Failure judgement
Conversion to Engineering Units
Measured value: Output value x 26.7 (mA)
The lowest limit value: Not applicable
The highest limit value: Output value x 26.7 (mA)
DTC P0155: Test ID $12: Component ID $88
Test ID
$12
Test Limit Type and Component ID
$88
DTC
P0155
Test Description
Circuit check of A/F sensor heater by monitoring the sensor output current during heater on.
Conversion to Engineering Units
Measured value: Output value (Decimal) x 9.042 (mA)
The lowest limit value: Output value (Decimal) x 9.042 (mA)
The highest limit value: Not applicable
DTC P0155: Test ID $13: Component ID $08
Test ID
$13
Test Limit Type and Component ID
$08
DTC
P0155
Test Description
Circuit check of A/F sensor heater by monitoring the sensor output current during heater on.
Conversion to Engineering Units
Measured value: Output value (Decimal) x 9.042 (mA)
The lowest limit value: Not applicable
The highest limit value: Output value (Decimal) x 9.042 (mA)
DTC P0161: Test ID $1A: Component ID $86
Test ID
$1A
Test Limit Type and Component ID
$86
DTC
P0161
Test Description
Circuit check of secondary oxygen sensor heater by monitoring the sensor output current during heater on.
Store Timing
Normal judgement/Failure judgement
Conversion to Engineering Units
Measured value: Output value x 7.23 (mA)
The lowest limit value: Output value x 7.23 (mA)
The highest limit value: Not applicable
DTC P0161: Test ID $1B: Component ID $06
Test ID
$1B
Test Limit Type and Component ID
$06
DTC
P0161
Test Description
Circuit check of secondary oxygen sensor heater by monitoring the sensor output current during heater on.
Store Timing
Normal judgement/Failure judgement
Conversion to Engineering Units
Measured value: Output value x 7.23 (mA)
The lowest limit value: Not applicable
The highest limit value: Output value x 7.23 (mA)
DTC P0161: Test ID $1A: Component ID $89
Test ID
$1A
Test Limit Type and Component ID
$89
DTC
P0161
Test Description
Circuit check of secondary oxygen sensor heater by monitoring the sensor output current during heater on.
Store Timing
Normal judgement/Failure judgement
Conversion to Engineering Units
Measured value: Output value (Decimal) x 0.01 (A)
The lowest limit value: Output value (Decimal) x 0.01 (A)
The highest limit value: Not applicable
DTC P0161: Test ID $1B: Component ID $09
Test ID
$1B
Test Limit Type and Component ID
$09
DTC
P0161
Test Description
Circuit check of secondary oxygen sensor heater by monitoring the sensor output current during heater on.
Store Timing
Normal judgement/Failure judgement
Conversion to Engineering Units
Measured value: Output value (Decimal) x 0.01 (A)
The lowest limit value: Not applicable
The highest limit value: Output value (Decimal) x 0.01 (A)
DTC P1505: Test ID $48: Component ID $00
Test ID
$48
Test Limit Type and Component ID
00$
DTC
P1505
Test Description
Check of PCV system by comparing the estimated intake air volume with the actual intake air volume during idle condition.
Store Timing
Normal judgement/Failure judgement
Conversion to Engineering Units
Measured value: Output value x 0.03662 (l/min.)
The lowest limit value: Not applicable
The highest limit value: Output value x 0.03662 (l/min.)
DTC P2279: Test ID $48: Component ID $01
Test ID
$48
Test Limit Type and Component ID
$01
DTC
P2279
Test Description
Check of PCV system by comparing the estimated intake air volume with the actual intake air volume during idle condition.
Store Timing
Normal judgement/Failure judgement
Conversion to Engineering Units
Measured value: Output value x 0.10 (l/min.)
The lowest limit value: Not applicable
The highest limit value: Output value x 0.10 (l/min.)
DTC P0128, P1486: Test ID $4D: Component ID $80
Test ID
$4D
Test Limit Type and Component ID
$80
DTC
P0128, P1486
Test Description
Check of thermostat by monitoring the time interval until ECT sensor signal reaches target value.
Store Timing
Normal judgement
Conversion to Engineering Units
Measured value: Output value - 48 (°C)
The lowest limit value: Output value - 48 (°C)
The highest limit value: Not applicable
DTC P0128, P1486: Test ID $4E: Component ID $80
Test ID
$4E
Test Limit Type and Component ID
$80
DTC
P0128, P1486
Test Description
Check of thermostat by monitoring the difference between actual ECT and predicted ECT.
Store Timing
Normal judgement
Conversion to Engineering Units
Measured value: Output value - 48 (°C)
The lowest limit value: Output value - 48 (°C)
The highest limit value: Not applicable
DTC P0128, P1486: Test ID $4F: Component ID $80
Test ID
$4F
Test Limit Type and Component ID
$80
DTC
P0128, P1486
Test Description
Check of thermostat by monitoring the time interval until ECT sensor signal reaches target value.
Store Timing
Failure judgement
Conversion to Engineering Units
Measured value: Output value - 48 (°C)
The lowest limit value: Output value - 48 (°C)
The highest limit value: Not applicable
DTC P0128, P1486: Test ID $50: Component ID $00
Test ID
$50
Test Limit Type and Component ID
$00
DTC
P0128, P1486
Test Description
Check of thermostat by monitoring the difference between actual ECT and predicted ECT.
Store Timing
Failure judgement
Conversion to Engineering Units
Measured value: Output value x 1 (°C)
The lowest limit value: Not applicable
The highest limit value: Output value x 1 (°C)
DTC P0128: Test ID $4D: Component ID $81
Test ID
$4D
Test Limit Type and Component ID
$81
DTC
P0128
Test Description
Check of thermostat by monitoring the time interval until ECT sensor signal reaches target value.
Store Timing
Normal judgement
Conversion to Engineering Units
Measured value: Output value (Decimal) - 40 (°C)
The lowest limit value: Output value (Decimal) - 40 (°C)
The highest limit value: Not applicable
DTC P0128: Test ID $4E: Component ID $81
Test ID
$4E
Test Limit Type and Component ID
$81
DTC
P0128
Test Description
Check of thermostat by monitoring the difference between actual ECT and predicted ECT.
Store Timing
Normal judgement
Conversion to Engineering Units
Measured value: Output value (Decimal) - 40 (°C)
The lowest limit value: Output value (Decimal) - 40 (°C)
The highest limit value: Not applicable
DTC P0128: Test ID $4F: Component ID $81
Test ID
$4F
Test Limit Type and Component ID
$81
DTC
P0128
Test Description
Check of thermostat by monitoring the difference between actual ECT and predicted ECT.
Store Timing
Failure judgement
Conversion to Engineering Units
Measured value: Output value (Decimal) - 40 (°C)
The lowest limit value: Output value (Decimal) - 40 (°C)
The highest limit value: Not applicable
DTC P0128: Test ID $50: Component ID $01
Test ID
$50
Test Limit Type and Component ID
$01
DTC
P0128
Test Description
Check of thermostat by monitoring the difference between actual ECT and predicted ECT.
Store Timing
Failure judgement
Conversion to Engineering Units
Measured value: Output value (Decimal) x 1 (°C)
The lowest limit value: Not applicable
The highest limit value: Output value (Decimal) x 1 (°C)
DTC P0128, P1486: Test ID $5C: Component ID $00
Test ID
$5C
Test Limit Type and Component ID
$00
DTC
P0128, P1486
Test Description
Check of thermostat by monitoring the difference between actual ECT and predicted ECT.
Store Timing
Normal judgement
Conversion to Engineering Units
Measured value: Output value x 0.0195 (V)
The lowest limit value: Not applicable
The highest limit value: Output value x 0.0195 (V)
DTC P0128, P1486: Test ID $5D: Component ID $00
Test ID
$5D
Test Limit Type and Component ID
$00
DTC
P0128, P1486
Test Description
Check of thermostat by monitoring the difference between actual ECT and predicted ECT.
Store Timing
Normal judgement
Conversion to Engineering Units
Measured value: Output value x 0.0195 (V)
The lowest limit value: Not applicable
The highest limit value: Output value x 0.0195 (V)
DTC P0128, P1486: Test ID $5E: Component ID $00
Test ID
$5E
Test Limit Type and Component ID
$00
DTC
P0128, P1486
Test Description
Check of thermostat by monitoring the difference between actual ECT and predicted ECT.
Store Timing
Failure judgement
Conversion to Engineering Units
Measured value: Output value x 0.0195 (V)
The lowest limit value: Not applicable
The highest limit value: Output value x 0.0195 (V)
DTC P0128, P1486: Test ID $5F: Component ID $00
Test ID
$5F
Test Limit Type and Component ID
$00
DTC
P0128, P1486
Test Description
Check of thermostat by monitoring the difference between actual ECT and predicted ECT.
Store Timing
Failure judgement
Conversion to Engineering Units
Measured value: Output value x 1 (°C)
The lowest limit value: Not applicable
The highest limit value: Output value x 1 (°C)
DTC P0410: Test ID $58: Component ID $80
Test ID
$58
Test Limit Type and Component ID
$80
DTC
P0410
Test Description
Check of secondary air system by monitoring the air pump electric current sensor output while the air pump is operated.
Store Timing
Failure judgement
Conversion to Engineering Units
Measured value: Output value x 0.2930 (A)
The lowest limit value: Output value x 0.2930 (A)
The highest limit value: Not applicable
DTC P1410: Test ID $59: Component ID $00
Test ID
$59
Test Limit Type and Component ID
$00
DTC
P1410
Test Description
Check of secondary air system by monitoring the air pump electric current sensor output while the air pump is operated.
Store Timing
Failure judgement
Conversion to Engineering Units
Measured value: Output value x 0.2930 (A)
The lowest limit value: Not applicable
The highest limit value: Output value x 0.2930 (A)
DTC P0411: Test ID $5A: Component ID $80
Test ID
$5A
Test Limit Type and Component ID
$80
DTC
P0411
Test Description
Check of secondary air system by monitoring the air pump electric current sensor output after the secondary air valve is opened.
Store Timing
Normal judgement/Failure judgement
Conversion to Engineering Units
Measured value: Output value x 0.2930 (A)
The lowest limit value: Output value x 0.2930 (A)
The highest limit value: Not applicable
DTC P1419: Test ID $5B: Component ID $00
Test ID
$5B
Test Limit Type and Component ID
$00
DTC
P1419
Test Description
Check of secondary air system by compare bank 1 A/F sensor output and bank 2 A/F sensor output during idle condition.
Store Timing
Normal judgement/Failure judgement
Conversion to Engineering Units
Measured value: Output value x 2/ - 15
The lowest limit value: Output value x 2/ - 15
The highest limit value: Not applicable
DTC P1456: Test ID $21: Component ID $83
Test ID
$21
Test Limit Type and Component ID
$83
DTC
P1456
Test Description
Monitoring the fluctuation of fuel tank pressure sensor output before and after EVAP bypass solenoid valve is opened after engine starting with cold condition.
Store Timing
Normal judgement
Conversion to Engineering Units
Measured value: Output value x 0.488281 (mmHg)
The lowest limit value: Output value x 0.488281 (mmHg)
The highest limit value: Not applicable
DTC P1456: Test ID $26: Component ID $83
Test ID
$26
Test Limit Type and Component ID
$83
DTC
P1456
Test Description
Monitoring either of:
Store Timing
Normal judgement
Conversion to Engineering Units
Measured value: Output value x 0.488281 (mmHg)
The lowest limit value: Output value x 0.488281 (mmHg)
The highest limit value: Not applicable
DTC P1456: Test ID $27: Component ID $83
Test ID
$27
Test Limit Type and Component ID
$83
DTC
P1456
Test Description
Monitoring the fluctuation of fuel tank pressure sensor output before and after the EVAP bypass solenoid valve is opened, after fuel tank pressure check is completed in predetermined time after engine starting with cold condition
Store Timing
Normal judgement/Failure judgement
Conversion to Engineering Units
Measured value: Output value x 0.488281 (mmHg)
The lowest limit value: Output value x 0.488281 (mmHg)
The highest limit value: Not applicable
DTC P1456: Test ID $38: Component ID $03
Test ID
$38
Test Limit Type and Component ID
$03
DTC
P1456
Test Description
Monitoring the difference of fuel tank pressure sensor output in pressure retention mode after decompressing the fuel tank.
Store Timing
Failure judgement
Conversion to Engineering Units
Measured value: Output value x 0.488281 (mmHg)
The lowest limit value: Not applicable
The highest limit value: Output value x 0.488281 (mmHg)
DTC P1457: Test ID $29: Component ID $83
Test ID
$29
Test Limit Type and Component ID
$83
DTC
P1457
Test Description
Monitoring the fuel tank pressure sensor output when EVAP control canister vent shut valve is closed after releasing the pressure in EVAP vapor line.
Store Timing
Failure judgement
Conversion to Engineering Units
Measured value: Output value x 0.488281 - 62.500000 (mmHg)
The lowest limit value: Output value x 0.488281 - 62.500000 (mmHg)
The highest limit value: Not applicable
DTC P0497: Test ID $2D: Component ID $03
Test ID
$2D
Test Limit Type and Component ID
$03
DTC
P0497
Test Description
Purge flow check by monitoring fuel tank pressure sensor value while the engine is running.
Store Timing
Failure judgement
Conversion to Engineering Units
Measured value: Output value x 0.488281 - 62.500000 (mmHg)
The lowest limit value: Not applicable
The highest limit value: Output value x 0.488281 - 62.500000 (mmHg)
DTC P1457: Test ID $2E: Component ID $83
Test ID
$2E
Test Limit Type and Component ID
$83
DTC
P1457
Test Description
Monitoring the fluctuation of fuel tank pressure sensor output after opening EVAP bypass solenoid valve while maintaining decompressed pressure in EVAP vapor line.
Store Timing
Normal judgement/Failure judgement
Conversion to Engineering Units
Measured value: Output value x 0.488281 (mmHg)
The lowest limit value: Output value x 0.488281 (mmHg)
The highest limit value: Not applicable
DTC P1457: Test ID $2F: Component ID $83
Test ID
$2F
Test Limit Type and Component ID
$83
DTC
P1457
Test Description
Monitoring the fuel tank pressure sensor output when EVAP canister purge valve is closed. and EVAP bypass solenoid and EVAP canister vent shut valves are opened before decompressing pressure in EVAP vapor line.
Store Timing
Failure judgement
Conversion to Engineering Units
Measured value: Output value x 0.488281 - 62.500000 (mmHg)
The lowest limit value: Output value x 0.488281 - 62.500000 (mmHg)
The highest limit value: Not applicable
DTC P1456: Test ID $3A: Component ID $83
Test ID
$3A
Test Limit Type and Component ID
$83
DTC
P1456
Test Description
Monitoring the fluctuation of fuel tank pressure sensor before and after the EVAP bypass solenoid valve is opened after engine starting with cold condition.
Store Timing
Normal judgement/
Conversion to Engineering Units
Measured value: Output value x 0.488281 (mmHg)
The lowest limit value: Output value x 0.488281 (mmHg)
The highest limit value: Not applicable
DTC P1456: Test ID $3B: Component ID $83
Test ID
$3B
Test Limit Type and Component ID
$83
DTC
P1456
Test Description
Monitoring the difference between the sensor output when EVAP control canister vent shut and EVAP bypass solenoid valves are opened before performing tank leak check, and the sensor output during tank leak check.
Store Timing
Normal judgement
Conversion to Engineering Units
Measured value: Output value x 0.488281 (mmHg)
The lowest limit value: Output value x 0.488281 (mmHg)
The highest limit value: Not applicable
DTC P1456: Test ID $3C: Component ID $03
Test ID
$3C
Test Limit Type and Component ID
$03
DTC
P1456
Test Description
Monitoring the valve calculated by dividing the difference of fuel tank pressure sensor output in pressure retention mode after decompressing the fuel tank by EVAP leak monitoring time.
Store Timing
Normal judgement/Failure judgement
Conversion to Engineering Units
Measured value: No unit
The lowest limit value: Not applicable
The highest limit value: No unit
DTC P1457: Test ID $3E: Component ID $83
Test ID
$3E
Test Limit Type and Component ID
$83
DTC
P1457
Test Description
Monitoring the fluctuation of fuel tank pressure sensor output after opening EVAP bypass solenoid valve while maintaining decompressing pressure in EVAP vapor line.
Store Timing
Normal judgement/Failure judgement
Conversion to Engineering Units
Measured value: Output value x 0.488281 (mmHg)
The lowest limit value: Output value x 0.488281 (mmHg)
The highest limit value: Not applicable
DTC P0496: Test ID $81: Component ID $80
Test ID
$81
Test Limit Type and Component ID
$80
DTC
P0496
Test Description
EVAP canister purge valve "stuck open" check by monitoring fuel tank pressure sensor while the engine is running.
Store Timing
Normal judgement/Failure judgement
Conversion to Engineering Units
Measured value: Output value (Decimal) x 0.1 (mmHg) - 3276.8 (mmHg)
The lowest limit value: Output value (Decimal) x 0.1 (mmHg) - 3276.8 (mmHg)
The highest limit value: Not applicable
DTC P2422: Test ID $82: Component ID $80
Test ID
$82
Test Limit Type and Component ID
$80
DTC
P2422
Test Description
EVAP canister purge valve "stuck close" check by monitoring fuel tank pressure sensor while the engine is running.
Store Timing
Normal judgement/Failure judgement
Conversion to Engineering Units
Measured value: Output value (Decimal) x 0.1 (mmHg) - 3276.8 (mmHg)
The lowest limit value: Output value (Decimal) x 0.1 (mmHg) - 3276.8 (mmHg)
The highest limit value: Not applicable
DTC P2422: Test ID $8F: Component ID $80
Test ID
$8F
Test Limit Type and Component ID
$80
DTC
P2422
Test Description
EVAP canister purge valve "stuck close" check by monitoring fuel tank pressure sensor at engine start.
Store Timing
Failure judgement
Conversion to Engineering Units
Measured value: Output value (Decimal) x 0.1 (mmHg) - 3276.8 (mmHg)
The lowest limit value: Output value (Decimal) x 0.1 (mmHg) - 3276.8 (mmHg)
The highest limit value: Not applicable
DTC P0497: Test ID $83: Component ID $00
Test ID
$83
Test Limit Type and Component ID
$00
DTC
P0497
Test Description
Monitoring the difference of fuel tank pressure sensor value when integrated value of purge flow rate reaches more than certain level after engine starts with cold condition and then the tank is decompressed to certain level, and intake air is opened.
Store Timing
Normal judgement/Failure judgement
Conversion to Engineering Units
Measured value: Output value (Decimal) x 0.1 (mmHg) - 3276.8 (mmHg)
The lowest limit value: Not applicable
The highest limit value: Output value (Decimal) x 0.1 (mmHg) - 3276.8 (mmHg)
DTC P0457: Test ID $85: Component ID $00
Test ID
$85
Test Limit Type and Component ID
$00
DTC
P0457
Test Description
Gross leak check of EVAP system by monitoring the fuel tank pressure sensor value while the engine is running.
Store Timing
Normal judgement/Failure judgement
Conversion to Engineering Units
Measured value: Output value (Decimal) x 0.1 (mmHg) - 3276.8 (mmHg)
The lowest limit value: Not applicable
The highest limit value: Output value (Decimal) x 0.1 (mmHg) - 3276.8 (mmHg)
DTC P0455: Test ID $86: Component ID $00
Test ID
$86
Test Limit Type and Component ID
$00
DTC
P0455
Test Description
Leak check of EVAP system by monitoring the fuel tank pressure sensor signal while EVAP system is decompression.
Store Timing
Normal judgement/Failure judgement
Conversion to Engineering Units
Measured value: Output value (Decimal) x 0.1 (mmHg)
The lowest limit value: Not applicable
The highest limit value: Output value (Decimal) x 0.1 (mmHg)
DTC P0456: Test ID $87: Component ID $00
Test ID
$87
Test Limit Type and Component ID
$00
DTC
P0456
Test Description
Leak check of EVAP system by monitoring the fuel tank pressure sensor value during the soak period after the engine is turned off. (EONV)
Store Timing
Normal judgement/Failure judgement
Conversion to Engineering Units
Measured value: Output value (Decimal) / 16384
The lowest limit value: Not applicable
The highest limit value: Output value (Decimal) / 16384
DTC P0497: Test ID $88: Component ID $00
Test ID
$88
Test Limit Type and Component ID
$00
DTC
P0497
Test Description
Purge flow check by monitoring fuel tank pressure sensor value while the engine is running.
Store Timing
Normal judgement/Failure judgement
Conversion to Engineering Units
Measured value: Output value (Decimal) x 0.1 (mmHg) - 3276.8 (mmHg)
The lowest limit value: Not applicable
The highest limit value: Output value (Decimal) x 0.1 (mmHg) - 3276.8 (mmHg)
DTC P0457: Test ID $8B: Component ID $00
Test ID
$8B
Test Limit Type and Component ID
$00
DTC
P0457
Test Description
Loose fuel cap check or gross leak check of EVAP system by monitoring the fuel tank pressure sensor signal while EVAP system is decompressing.
Store Timing
Failure judgement
Conversion to Engineering Units
Measured value: Output value (Decimal) x 0.1 (mmHg) - 3276.8 (mmHg)
The lowest limit value: Not applicable
The highest limit value: Output value (Decimal) x 0.1 (mmHg) - 3276.8 (mmHg)
DTC P0457: Test ID $8D: Component ID $00
Test ID
$8D
Test Limit Type and Component ID
$00
DTC
P0457
Test Description
Gross leak check of EVAP system by monitoring the fuel tank pressure sensor value after decompress mode.
Store Timing
Normal judgement/Failure judgement
Conversion to Engineering Units
Measured value: Output value (Decimal) x 0.1 (mmHg) - 3276.8 (mmHg)
The lowest limit value: Not applicable
The highest limit value: Output value (Decimal) x 0.1 (mmHg) - 3276.8 (mmHg)
DTC P0442: Test ID $90: Component ID $00
Test ID
$90
Test Limit Type and Component ID
$00
DTC
P0442
Test Description
Leak check of EVAP system by monitoring the fuel tank pressure sensor value before purge started.
Store Timing
Normal judgement
Conversion to Engineering Units
Measured value: Output value (Decimal) x 0.1 (mmHg) - 3276.8 (mmHg)
The lowest limit value: Not applicable
The highest limit value: Output value (Decimal) x 0.1 (mmHg) - 3276.8 (mmHg)
DTC P0442: Test ID $91: Component ID $80
Test ID
$91
Test Limit Type and Component ID
$80
DTC
P0442
Test Description
Leak check of EVAP system by monitoring the fuel tank pressure sensor value while the engine is running.
Store Timing
Normal judgement
Conversion to Engineering Units
Measured value: Output value (Decimal) x 0.1 (mmHg) - 3276.8 (mmHg)
The lowest limit value: Output value (Decimal) x 0.1 (mmHg) - 3276.8 (mmHg)
The highest limit value: Not applicable
DTC P0442: Test ID $92: Component ID $80
Test ID
$92
Test Limit Type and Component ID
$80
DTC
P0442
Test Description
Leak check of EVAP system by monitoring the fuel tank pressure sensor value during the decompression mode.
Store Timing
Failure judgement
Conversion to Engineering Units
Measured value: Output value (Decimal) x 0.1 (mmHg) - 3276.8 (mmHg)
The lowest limit value: Output value (Decimal) x 0.1 (mmHg) - 3276.8 (mmHg)
The highest limit value: Not applicable
DTC P0442: Test ID $93: Component ID $00
Test ID
$93
Test Limit Type and Component ID
$00
DTC
P0442
Test Description
Leak check of EVAP system by monitoring the fuel tank pressure sensor value during the decompression mode.
Store Timing
Normal judgement/Failure judgement
Conversion to Engineering Units
Measured value: Output value (Decimal) x 0.1 (mmHg/min.)
The lowest limit value: Not applicable
The highest limit value: Output value (Decimal) x 0.1 (mmHg/min.)
DTC P0456: Test ID $94: Component ID $00
Test ID
$94
Test Limit Type and Component ID
$00
DTC
P0456
Test Description
Leak check of EVAP system by monitoring the fuel tank pressure sensor value while the engine is running.
Store Timing
Normal judgement
Conversion to Engineering Units
Measured value: Output value (Decimal) x 0.1 (mmHg) - 3276.8 (mmHg)
The lowest limit value: Not applicable
The highest limit value: Output value (Decimal) x 0.1 (mmHg) - 3276.8 (mmHg)
DTC P0456: Test ID $95: Component ID $80
Test ID
$95
Test Limit Type and Component ID
$80
DTC
P0456
Test Description
Leak check of EVAP system by monitoring the fuel tank pressure sensor value during the decompression mode.
Store Timing
Failure judgement
Conversion to Engineering Units
Measured value: Output value (Decimal) x 0.1 (mmHg) - 3276.8 (mmHg)
The lowest limit value: Output value (Decimal) x 0.1 (mmHg) - 3276.8 (mmHg)
The highest limit value: Not applicable
DTC P0456: Test ID $96: Component ID $00
Test ID
$96
Test Limit Type and Component ID
$00
DTC
P0456
Test Description
Leak check of EVAP system by monitoring the fuel tank pressure sensor value during the decompression mode.
Store Timing
Failure judgement
Conversion to Engineering Units
Measured value: Output value (Decimal) x 0.1 (mmHg/min.)
The lowest limit value: Not applicable
The highest limit value: Output value (Decimal) x 0.1 (mmHg/min.)
DTC P0456: Test ID $97: Component ID $00
Test ID
$97
Test Limit Type and Component ID
$00
DTC
P0456
Test Description
Leak check of EVAP system by monitoring the fuel tank pressure sensor value during the decompression mode.
Store Timing
Normal judgement
Conversion to Engineering Units
Measured value: Output value (Decimal) x 0.1 (mmHg/min.)
The lowest limit value: Not applicable
The highest limit value: Output value (Decimal) x 0.1 (mmHg/min.)
DTC P0456: Test ID $98: Component ID $00
Test ID
$98
Test Limit Type and Component ID
$00
DTC
P0456
Test Description
Monitoring 0.02 inch leak based on change of evaporative pressure after engine stops and an index indicated air opening failure including aberration of PTANK 0 point.
Store Timing
Normal judgement/Failure judgement
Conversion to Engineering Units
Measured value: Output value (Decimal) / 16384
The lowest limit value: Not Applicable
The highest limit value: Output value (Decimal) / 16384