2004-08 ELECTRICAL Relays - TSX <meta name="InColGX" content=""> </head> <body bgcolor="white" text="black"> <h1>2004-08 ELECTRICAL</h1> <h1>Relays - TSX</h1><a name="S41533820332008080900000"></a><h2 class="clsHeadOne">Power Relay Test</h2> <p>Use this chart to identify the type of relay, then do the test listed for it.</p> <p><span class="clsNote"><table> <tr> <td class="clsNoteLabel"><span>NOTE:</span></td> <td>For the turn signal/hazard relay input test (see <a class="clsExtHyperlink" id="A00293885_S13434139322008080900000">TURN SIGNAL/HAZARD RELAY INPUT TEST</a> ).</td> </tr> </table></span></p> <p><span class="clsArticleTable"><a name="S34857366762008080900000"></a><span class="clsTableTitle">RELAY REFERENCE CHART</span><br><table cellspacing="0" class="clsArticleTable58"> <colgroup> <col span="1" id="COL1" align="LEFT"> <col span="1" id="COL2" align="LEFT"> </colgroup> <thead> <tr class="clsTblHead"> <th align="CENTER" class="clsCellNormal">Relay</th> <th align="CENTER" class="clsCellNormal">Test</th> </tr> </thead> <tbody> <tr> <td align="LEFT" class="clsCellNormal">A/C compressor clutch relay</td> <td rowspan="14" align="LEFT" class="clsCellNormal">Normally-open type</td> </tr> <tr> <td align="LEFT" class="clsCellNormal">A/C condenser fan relay</td> </tr> <tr> <td align="" class="clsCellNormal">Accessory power socket relay</td> </tr> <tr> <td align="" class="clsCellNormal">Blower motor relay</td> </tr> <tr> <td align="" class="clsCellNormal">Fog lights relay ('06-08 models)</td> </tr> <tr> <td align="" class="clsCellNormal">Ignition coil relay</td> </tr> <tr> <td align="" class="clsCellNormal">A/F ratio sensor relay</td> </tr> <tr> <td align="" class="clsCellNormal">PGM-FI main relay 1, 2</td> </tr> <tr> <td align="" class="clsCellNormal">Power window relay</td> </tr> <tr> <td align="" class="clsCellNormal">Radiator fan relay</td> </tr> <tr> <td align="" class="clsCellNormal">Rear window defogger relay</td> </tr> <tr> <td align="" class="clsCellNormal">Starter cut relay</td> </tr> <tr> <td align="" class="clsCellNormal">Seat heater relay</td> </tr> <tr> <td align="" class="clsCellNormal">Throttle actuator control module relay</td> </tr> <tr> <td align="" class="clsCellNormal">Daytime running lights relay (Canada models)</td> <td rowspan="3" align="" class="clsCellNormal">Five-terminal type</td> </tr> <tr> <td align="LEFT" class="clsCellNormal">Moonroof close relay</td> </tr> <tr> <td align="" class="clsCellNormal">Moonroof open relay</td> </tr> </tbody> </table></span></p><a name="S34894747132008080900000"></a><h2 class="clsHeadTwo">Normally-open type</h2> <p>Check for continuity between the terminals.</p> <ul class="clsBULLET"> <li>There should be continuity between the No. 1 and No. 2 terminals when battery positive terminal is connected to the No. 4 terminal, and battery negative terminal is connected to the No. 3 terminal.</li> <li>There should be no continuity between the No. 1 and No. 2 terminals when power is disconnected.<p><span class="clsFig"><a class="clsExtGraphicLink" onclick="ajaxModalImg($(this).attr('id'))" id="G05492783" name="S08293019082008080900000">Fig. 1: Checking Continuity Between Terminals - Normally-Open Type</a></span></p> </li> </ul><a name="S38082835192008080900000"></a><h2 class="clsHeadTwo">Five-terminal type</h2> <p>Check for continuity between the terminals.</p> <ul class="clsBULLET"> <li>There should be continuity between the No. 1 and No. 2 terminals when battery positive terminal is connected to the No. 5 terminal, and battery negative terminal is connected to the No. 3 terminal.</li> <li>There should be continuity between the No. 1 and No. 4 terminals when power is disconnected.<p><span class="clsFig"><a class="clsExtGraphicLink" onclick="ajaxModalImg($(this).attr('id'))" id="G05492784" name="S05585645852008080900000">Fig. 2: Checking Continuity Between Terminals - Five-Terminal Type</a></span></p> </li> </ul> </body> </html>

Mitchell onDemand(proDemand) web-online. Is free

DATACENTER ERROR!!! Внимание! Авария в датацентре!!


Subscribe to the telegram channel https://t.me/kolhosniki_en

Place for your advertisement

predsedatel@kolhosniki.ru
Click for start

RELAYS

  • HEADINGS
    • Power Relay Test
      • Normally-open type
      • Five-terminal type
  • FIGURES
    • Fig. 1: Checking Continuity Between Terminals - Normally-Open Type
    • Fig. 2: Checking Continuity Between Terminals - Five-Terminal Type
  • TABLES
    • RELAY REFERENCE CHART

2004-08 ELECTRICAL

Relays - TSX

Power Relay Test

Use this chart to identify the type of relay, then do the test listed for it.

NOTE: For the turn signal/hazard relay input test (see TURN SIGNAL/HAZARD RELAY INPUT TEST ).

RELAY REFERENCE CHART
Relay Test
A/C compressor clutch relay Normally-open type
A/C condenser fan relay
Accessory power socket relay
Blower motor relay
Fog lights relay ('06-08 models)
Ignition coil relay
A/F ratio sensor relay
PGM-FI main relay 1, 2
Power window relay
Radiator fan relay
Rear window defogger relay
Starter cut relay
Seat heater relay
Throttle actuator control module relay
Daytime running lights relay (Canada models) Five-terminal type
Moonroof close relay
Moonroof open relay

Normally-open type

Check for continuity between the terminals.

  • There should be continuity between the No. 1 and No. 2 terminals when battery positive terminal is connected to the No. 4 terminal, and battery negative terminal is connected to the No. 3 terminal.
  • There should be no continuity between the No. 1 and No. 2 terminals when power is disconnected.

    Fig. 1: Checking Continuity Between Terminals - Normally-Open Type

Five-terminal type

Check for continuity between the terminals.

  • There should be continuity between the No. 1 and No. 2 terminals when battery positive terminal is connected to the No. 5 terminal, and battery negative terminal is connected to the No. 3 terminal.
  • There should be continuity between the No. 1 and No. 4 terminals when power is disconnected.

    Fig. 2: Checking Continuity Between Terminals - Five-Terminal Type

Didn't find what you were looking for? Try to find in:
- Alldata Online (Beta)
Loading...

This project exists mainly due to the display of advertising.

Due to the international situation, making a profit from advertising has become impossible.

If this continues, then the project will either close completely, or become closed and paid.

To support the project, you can Buy a paid subscription


Can be closed in 20