e-Golf Current Flow Diagram No.  15 / 1
09.2014

Climatronic with 2-zone temperature control
From March 2014

e-Golf Current Flow Diagram No.  15 / 2
ws = white
sw = black
ro = red
rt = red
br = brown
gn = green
bl = blue
gr = grey
li = purple
vi = purple
ge = yellow
or = orange
rs = pink
 
 
 
 
 
Heater and air conditioning controls, Sunlight penetration photosensor, Left vent temperature sender, Right vent temperature sender, Climatronic control unit, Data bus diagnostic interface, Fuse 7 on fuse holder C, Fuse 14 on fuse holder C, Fuse 34 on fuse holder C
EX21 -   Heater and air conditioning controls
G107 -   Sunlight penetration photosensor
G150 -   Left vent temperature sender
G151 -   Right vent temperature sender
J255 -   Climatronic control unitK00592300805#BTJ255
J533 -   Data bus diagnostic interfaceK00592300805#BTJ533
SC7 -   Fuse 7 on fuse holder CK00592300802#BTSC-
SC14 -   Fuse 14 on fuse holder CK00592300802#BTSC-
SC34 -   Fuse 34 on fuse holder CK00592300802#BTSC-
SB35 -   Fuse 35 on fuse holder BK00592300802#BTSB-
T2do -   2-pin connector
T2dp -   2-pin connector
T6ch -   6-pin connector
T20 -   20-pin connector
T20c -   20-pin connector
  244 -   Earth connection (sender earth), in Climatronic wiring harness
  A164 -   Positive connection 2 (30a) in dash panel wiring harness
  B398 -   Connection 2 (convenience CAN bus, high), in main wiring harness
  B407 -   Connection 2 (convenience CAN bus, low), in main wiring harness
  B506 -   Connection (convenience CAN bus, high), in interior wiring harness
  B507 -   Connection (convenience CAN bus, low), in interior wiring harness

e-Golf Current Flow Diagram No.  15 / 3
ws = white
sw = black
ro = red
rt = red
br = brown
gn = green
bl = blue
gr = grey
li = purple
vi = purple
ge = yellow
or = orange
rs = pink
 
 
 
 
 
Charging unit 1 for high-voltage battery, Heater and air conditioning controls, Air conditioning system relay, Climatronic control unit, Control unit for air conditioning compressor
AX4 -   Charging unit 1 for high-voltage batteryK00592300804#BTAX4
A11 -   Onboard supply charger unit
EX21 -   Heater and air conditioning controls
J32 -   Air conditioning system relayK00592300803#BTJ32
J255 -   Climatronic control unitK00592300805#BTJ255
J842 -   Control unit for air conditioning compressorK00592300804#BTJ842
T5az -   5-pin connector
T5ba -   5-pin connector
T8v -   8-pin connector
T8x -   8-pin connector
T14p -   14-pin connector, blackK00592300807#BTT14p
T14s -   14-pin connector, blackK00592300807#BTT14s
T17f -   17-pin connector, redK00592300807#BTT17f
T17n -   17-pin connector, redK00592300807#BTT17n
T20c -   20-pin connector
TIUL -   Coupling point in interior, below left
TML -   Coupling point in engine compartment, left
V470 -   Electrical air conditioner compressor
Z115 -   High-voltage heater (PTC)
  85 -   Earth connection 1, in engine compartment wiring harness
  281 -   Earth point 1, engine prewiring harness
  283 -   Earth point 2, engine prewiring harness
  317 -   Earth connection 7, in engine compartment wiring harness
  777 -   Earth point for air conditioner compressorK00592300801#VB777
  803 -   Earth point on cross member for drive motorK00592300801#VB803
  B350 -   Positive connection 1 (87a) in main wiring harness
  B711 -   Connection 6 (LIN bus) in main wiring harness

e-Golf Current Flow Diagram No.  15 / 4
ws = white
sw = black
ro = red
rt = red
br = brown
gn = green
bl = blue
gr = grey
li = purple
vi = purple
ge = yellow
or = orange
rs = pink
 
 
 
 
 
Heater and air conditioning controls, Air quality sensor, Pressure sender for refrigerant circuit, Fresh air blower control unit, Climatronic control unit
EX21 -   Heater and air conditioning controls
G238 -   Air quality sensor
G805 -   Pressure sender for refrigerant circuit
J126 -   Fresh air blower control unitK00592300805#BTJ126
J255 -   Climatronic control unitK00592300805#BTJ255
T2dq -   2-pin connector
T3as -   3-pin connector
T3ck -   3-pin connector
T4dc -   4-pin connector
T17e -   17-pin connector, brownK00592300807#BTT17e
T17f -   17-pin connector, redK00592300807#BTT17f
T17m -   17-pin connector, brownK00592300807#BTT17m
T17n -   17-pin connector, redK00592300807#BTT17n
T20c -   20-pin connector
TIUL -   Coupling point in interior, below left
  131 -   Earth connection 2, in engine compartment wiring harness
  179 -   Earth connection, in left headlight wiring harness
  317 -   Earth connection 7, in engine compartment wiring harness
  638 -   Earth point, on right A-pillarK00592300801#VB638
  673 -   Earth point 3, on front of left longitudinal memberK00592300801#VB673
  A38 -   Positive connection 2 (15a) in dash panel wiring harness
  A209 -   Connection 1 (LIN bus) in dash panel wiring harness
  B710 -   Connection 5 (LIN bus) in main wiring harness
  U26 -   Connection (15), in gearbox switch wiring harness

e-Golf Current Flow Diagram No.  15 / 5
ws = white
sw = black
ro = red
rt = red
br = brown
gn = green
bl = blue
gr = grey
li = purple
vi = purple
ge = yellow
or = orange
rs = pink
 
 
 
 
 
Heater and air conditioning controls, Potentiometer for front air distribution flap control motor, Potentiometer for fresh air/air recirculation, air flow flap control motor, Climatronic control unit, Fresh air blower, Fresh air/air recirculation, air flow flap control motor, Front air distribution flap control motor
EX21 -   Heater and air conditioning controls
G642 -   Potentiometer for front air distribution flap control motor
G644 -   Potentiometer for fresh air/air recirculation, air flow flap control motor
J255 -   Climatronic control unitK00592300805#BTJ255
T2dr -   2-pin connector
T6n -   6-pin connector
T6r -   6-pin connector
T16c -   16-pin connector
T16d -   16-pin connector
T20c -   20-pin connector
V2 -   Fresh air blower
V425 -   Fresh air/air recirculation, air flow flap control motor
V426 -   Front air distribution flap control motor
  278 -   Earth connection 4, in interior wiring harness
  810 -   Earth point on central tube for dash panel, centre leftK00592300801#VB810
  811 -   Earth point on central tube for dash panel, centre rightK00592300801#VB811
  L7 -   Connection 3, in evaporator housing unit wiring harness
  L8 -   Connection 4, in evaporator housing unit wiring harness
* -   Only left-hand drive models
*2 -   Only right-hand drive models

e-Golf Current Flow Diagram No.  15 / 6
ws = white
sw = black
ro = red
rt = red
br = brown
gn = green
bl = blue
gr = grey
li = purple
vi = purple
ge = yellow
or = orange
rs = pink
 
 
 
 
 
Heater and air conditioning controls, Potentiometer for defroster flap control motor, Footwell vent temperature sender, Potentiometer for left temperature flap control motor, Evaporator temperature sensor, Climatronic control unit, Defroster flap control motor, Left temperature flap control motor
EX21 -   Heater and air conditioning controls
G135 -   Potentiometer for defroster flap control motor
G192 -   Footwell vent temperature sender
G220 -   Potentiometer for left temperature flap control motor
G308 -   Evaporator temperature sensor
J255 -   Climatronic control unitK00592300805#BTJ255
T2dt -   2-pin connector
T2du -   2-pin connector
T6p -   6-pin connector
T6q -   6-pin connector
T16c -   16-pin connector
T16d -   16-pin connector
V107 -   Defroster flap control motor
V158 -   Left temperature flap control motor
  L7 -   Connection 3, in evaporator housing unit wiring harness
  L8 -   Connection 4, in evaporator housing unit wiring harness

e-Golf Current Flow Diagram No.  15 / 7
ws = white
sw = black
ro = red
rt = red
br = brown
gn = green
bl = blue
gr = grey
li = purple
vi = purple
ge = yellow
or = orange
rs = pink
 
 
 
 
 
Heater and air conditioning controls, Potentiometer for right temperature flap control motor, Climatronic control unit, Right temperature flap control motor
EX21 -   Heater and air conditioning controls
G221 -   Potentiometer for right temperature flap control motor
J255 -   Climatronic control unitK00592300805#BTJ255
T6u -   6-pin connector
T16c -   16-pin connector
T16d -   16-pin connector
V159 -   Right temperature flap control motor
  L7 -   Connection 3, in evaporator housing unit wiring harness
  L8 -   Connection 4, in evaporator housing unit wiring harness

Didn't find what you were looking for? Try to find in:
- Mitchell onDemand online


- ETKA ONLINE - login-pass from kolhosniki.ru

- NEW ELSA ONLINE - login-pass from kolhosniki.ru
Loading...

This project exists mainly due to the display of advertising.

Due to the international situation, making a profit from advertising has become impossible.

If this continues, then the project will either close completely, or become closed and paid.

To support the project, you can Buy a paid subscription


Can be closed in 20